Model IS - Intelligent Scanner
Weitere Informationen erhalten Sie telefonisch oder auf Anfrage
The Intelligent Scanner is an industrial barcode reader including OCR/OCV capabilities, reading up to 200 codes per second. Powerful OCR feature achieves absolute accuracy even in less than ideal industrial environments. Character voids and blemishes, poor lighting and background inconsistencies present no problems for the Intelligent Scanner. Automatic identification and data capture by reading bar codes, Data Matrix and OCR characters to communicate coordinate information to motion control, SPC, HMI and PLC packages. The Intelligent Scanner interprets popular code formats including: • 1D Formats and 1D Barcode Grading • BC 412 • Codabar • Code 39 and Code 128 • ECC200 and older ECC formats • Interleave 2-of-5 • Pharmacode • PDF-417 Stacked Barcode • Snowflake 2D Codes • UPC/EAN To measure code quality or integrity, the Intelligent Scanner outputs the number of errors in the code that the algorithm had to correct. Built-in Ethernet communications means easy integration with the existing plant network and seamless data transfer.
Legend IS Specifications
|
Size |
112mm x 60mm x 30mm (not including lens) |
|
Mounting |
Four M4 threaded holes (on the back of unit), 7.9mm depth |
|
Weight |
170g/6oz (without lens or integrated light) |
|
Power Requirements |
24V DC, 210mA (or minimum 5W supply), regulated and isolated. Additional 5W required for integrated light option. |
|
Operating Temperatures |
Operating Temperature: 0-45o C, 32-113o F |
|
Image Sensor |
4.8mm x 3.6mm (1/3" format) CCD, 640 x 480 pixel resolution, 7.4µm x 7.4 µm pixels |
|
Electronic Shuttering |
10 µs – 1 second exposure times |
|
Optics |
CS mount standard, C mount-capable with optional adaptor |
|
External Port |
RJ-45 for 10/100 Mbps Ethernet communications, 10 pin keyed modular connector for power and digital I/O |
|
Digital I/O |
24V DC regulated, 8 configurable inputs and outputs, NPN (current sinking) inputs, PNP (current sourcing) outputs, active high signals. Inputs can sink up to 1.5mA and outputs source a maximum of 50 mA |
|
User Interface |
Win98/2k/NT, Framework Software |
|
Certifications |
CE certified |